EUROPE


High grade range

A-series

A new standard created by listening to our customers.
A wider range of test requirements and higher test specifications.
A-series meets the needs for such a versatile test environment.
Advanced automatic energy saving, high level of functionality and a protected test environment.
A series improves the working environment of vibration testing.

K2

Features

① Improvement of performance
  • ■ Improvement in excitation force

    When compared with the conventional i & J series, the A series increases the relative excitation force.

    ・Increased force per system power requirement
    ・Increased force per system mass
    ・Increased force per system size

    Improvement in excitation force

  • ■ Standard 76.2 mmp-p displacement
    *Only for A30, A45, A65, A74

    A-series has a displacement of 76.2 mmp-p (3 inch stroke) which gives good balance between specification of velocity, acceleration and displacement. This single system can be used in a very wide variety of tests.

    Standard 76.2mmp-p displacement

  • ■ Increase in frequency range

    In addition to the increased displacement of 76.2 mmp-p, the maximum frequency range is also increased when compared to the i, and J-series.

    Increase in frequency range

  • ■ Cross-axis acceleration reduction

    A series dramatically reduces cross-axis (crosstalk) acceleration (horizontal vibration). Highly accurate testing is achieved.

    Cross-axis acceleration reduction

  • ■ High velocity shock testing *Only for A30, A45, A65, A74

    Where a test requires a high shock velocity, traditional shaker systems use a matching transformer to achieve the necessary higher armature voltage.
    Since IMV’s ECO-system has complete control over the field level, the field value can be adjusted to increase the maximum shock velocity capability of the system. By entering the specified shock profile into IMV’s K2 controller. The field level in the shaker is automatically adjusted to ensure that the required velocity is achieved. A-series (EM amplifier model) provides a maximum of 4.6 m/s shock velocity testing.

    Example of shock test

    i-series
    (conventional)
    Model i240/SA3M i250/SA5M i260/SA7M No applicable product
    Rated Force
    Shock (kN)
    48 80 108 -
    Maximum Velocity Shock (m/s) 2.2 2.2 2.2 -
    Maximum Displacement
    (mmp-p)
    51 51 51 -
    Maximum Load
    (kg)
    Not achievable
    *not enough velocity
    *not enough displacement
    Not achievable
    *not enough velocity
    *not enough displacement
    Not achievable
    *not enough velocity
    *not enough displacement
    -
    J-series
    (conventional)
    Model J240/SA4M J250/SA6M J260/SA7M No applicable product
    Rated Force
    Shock (kN)
    55 80 108 -
    Maximum Velocity Shock (m/s) 2.4 2.4 24 -
    Maximum Displacement
    (mmp-p)
    100 100 100 -
    Maximum Load
    (kg)
    Not achievable
    *not enough velocity
    Not achievable
    *not enough velocity
    Not achievable
    *not enough velocity
    -
    A-series Model A30/EM3HM A45/EM5HM A65/EM7HM A74/EM10HM
    Rated Force
    Shock (kN)
    60(50) 90(80) 130(120) 180(160)
    Maximum Velocity
    Shock (m/s)
    2.5(3.5) 2.5(3.5) 2.5(3.5) 2.5(3.5)
    Maximum Displacement
    (mmp-p)
    76.2 76.2 76.2 76.2
    Maximum Load (kg) 18 31 50 89
② User friendly and Secure
  • ■ Lower power consumption

    In comparison with the same class of conventional systems (i,J-series), the A-series achieves lower power consumption. With an automatic energy-saving function increased energy saving is achieved across all force ranges.

    Lower power consumption

  • ■ International safety standards

    A-series complies with international safety standards.

    International safety standards

③ User first principle

LAUNCHER

Rapid creation of a test from a set of pre-defined templates conforming to most international test standards.

User friendly and Secure

SYSTEM MONITOR

Remote monitoring of the test status over the internet.

The status of the test, and the amplifier or shaker operation can be viewed on a remote PC using a standard internet browser.
Problems or errors are easily identified.

  • Home screen

    Home screen

  • Home screen(Error)

    Home screen(Error)

  • Eco screen

    Eco screen

  • Camera screen

    Camera screen

  • Manual link screen

    Chamber screen

Promotion Movie

Table Insert Pattern (Unit:mm)

Table Insert Pattern

Specifications

  System Model A03/SA1MM A10/SA1HM A10/EM1HM A20/SA2HM A20/EM2HM
  Data Sheet
  Frequency Range(Hz) 0-4000 0-4500*4 0-4500*4 0-3300 0-3300
System
Specifications
Rated
Force
Sine(kN) 3 10 10 20 20
Random
(kN rms)*1
3 10 10 20 20
Shock(kN) 9 20 20 40 40
High Velocity
Shock(kN)
- - 16 - 32
Maximum
Acc.
Sine(m/s2) 1000 900 900 900 900
Random
(m/s2 rms)
700 630 630 630 630
Shock
(m/s2 peak)
2000 1818 1818 1818 1818
High Velocity
Shock(m/s2 peak)
- - 1454 - 1454
Maximum
Vel.
Sine(m/s) 2.0 2.0 2.0 2.0 2.0
Shock
(m/s peak)
2.3 2.5 2.5 2.5 2.5
High Velocity
Shock(m/s peak)
- - 3.5 - 3.5
Maximum
Dsp.
Sine(mmp-p) 30 51 51 51 51
Maximum Travel
(mmp-p)
40 64 64 66 66
Maximum Load(kg) 120 200 200 300 300
Power Requirements
(kVA)*2
8.7 20.4 20.4 30 30
Breaker Capacity(A)*3 40 75 75 125 125
Vibration
Generator
Model A03 A10 A10 A20 A20
Armature Mass(Kg) 3 11 11 22 22
Armature Diameter(φmm) 128 210 210 280 280
Allowable Eccentric
Moment(N・m)
160 294 294 700 700
Dimensions(mm)
WxHxD
868x700x500 946x827x676 946x827x676 1038x920x775 1038x920x775
Shaker Body
Diameter(mm)
480 585 585 678 678
Mass(kg) 400 1080 1080 1600 1600
Power
Amplifier
Model SA1MM-A03 SA1HM-A10 EM1HM-A10 SA2HM-A20 EM2HM-A20
Maximum Output(kVA) 5.4 11 11 21 21
Dimensions(mm)
WxHxD
580x1950x850 580x1950x850 580x1950x850 580x1950x850 580x1950x850
Mass(kg) 240 280 330 350 410
Controller Vibration Controller See Vibration Controller K2
Cooling Cooling Method Air cooling
  Blower Dimensions
(mm)WxHxD*6
600x1905x613 1045x2285x711 1045x2285x711 931x2175x538 931x2175x538
Mass(kg) 45 150 150 150 150
Wattage(kw) 0.4 3.7 3.7 5.5 5.5
Duct Hose
Diameter(φ)
125 125 125 200 200
  System Model A30/SA3HM A30/EM3HM A45/SA5HM A45/EM5HM
  Data Sheet
  Frequency Range(Hz) 0-2600 0-2600 0-2600 0-2600
System
Specifications
Rated
Force
Sine(kN) 30 30 45 45
Random
(kN rms)*1
30 30 45 45
Shock(kN) 60 60 90 90
High Velocity
Shock(kN)
- 50 - 80
Maximaum
Acc.
Sine(m/s2) 900 900 900 900
Random
(m/s2 rms)
630 630 630 630
Shock
(m/s2 peak)
1818 1818 1800 1800
High Velocity
Shock(m/s2 peak)
- 1515 - 1600
Maximum
Vel.
Sine(m/s) 2.0 2.0 2.0 2.0
Shock
(m/s peak)
2.5 2.5 2.5 2.5
High Velocity
Shock(m/s peak)
- 3.5 - 3.5
Maximum
Dsp.
Sine(mmp-p) 76.2 76.2 76.2 76.2
Maximum
Travel
(mmp-p)
82 82 82 82
Maximum Load(kg) 400 400 600 600
Power Requirements
(kVA)*2
36 36 57 57
Breaker Capacity(A)*3 125 125 200 200
Vibration
Generator
Model A30 A30 A45 A45
Armature Mass(Kg) 33 33 50 50
Armature Diameter
(φmm)
290 290 436 436
Allowable Eccentric
Moment(N・m)
850 850 1550 1550
Dimensions
(mm)WxHxD
1100x1048x840 1100x1048x840 1232x1215x1040 1232x1215x1040
Shaker Body
Diameter(mm)
725 725 825 825
Mass(kg) 2000 2000 3000 3000
Power
Amplifier
Model SA3HM-A30 EM3HM-A30 SA5HM-A45 EM5HM-A45
Maximum
Output(kVA)
31 31 44 44
Dimensions
(mm)WxHxD
580x1950x850 580x1950x850 580x1950x850 1160x1950x850
Mass(kg) 420 500 900 1000
Controller Vibration Controller See Vibration Controller K2
Cooling Cooling Method Air cooling
Blower Dimensions
(mm)WxHxD*6
931x2175x538 931x2175x538 1160x2405x787 1160x2405x787
Mass(kg) 150 150 250 250
Wattage(kw) 5.5 5.5 11 11
Duct Hose
Diameter(φ)
200 200 250 250
  System Model A65/SA6HM ** A65/EM7HM ** A74/EM8HM ** A74/EM10HM **
  Data Sheet  
  Frequency Range(Hz) 0-2600*5 0-2600*5 0-2600*5 0-2600*5
System
Specifications
Rated
Force
Sine(kN) 65 65 74 74
Random
(kN rms)*1
65 65 74 74
Shock(kN) 130 130 148 180
High Velocity
Shock(kN)
- 120 120 160
Maximaum
Acc.
Sine(m/s2) 900 900 1000 1000
Random
(m/s2 rms)
630 630 630 630
Shock
(m/s2 peak)
1806 1806 2000 2432
High Velocity
Shock(m/s2 peak)
- 1666 1621 2162
Maximum
Vel.
Sine(m/s) 2.0 2.0 2.0 2.0
Shock
(m/s peak)
2.5 2.5 2.5 2.5
High Velocity
Shock(m/s peak)
- 3.5 3.5 3.5
Maximum
Dsp.
Sine(mmp-p) 76.2 76.2 76.2 76.2
Maximum
Travel
(mmp-p)
82 82 82 82
Maximum Load(kg) 1000 1000 1000 1000
Power Requirements
(kVA)*2
83 83 100 100
Breaker Capacity(A)*3 300 300 350 350
Vibration
Generator
Model A65 A65 A74 A74
Armature Mass(Kg) 72 72 74 74
Armature Diameter
(φmm)
446 446 446 446
Allowable Eccentric
Moment(N・m)
1550 1550 1550 1550
Dimensions
(mm)WxHxD
1310x1253x1040 1310x1253x1040 1310x1253x1040 1310x1253x1040
Shaker Body
Diameter(mm)
925 925 925 925
Mass(kg) 3500 3500 3500 3500
Power
Amplifier
Model SA6HM-A65 EM7HM-A65 EM8HM-A74 EM10HM-A74
Maximum
Output(kVA)
68 68 100 100
Dimensions
(mm)WxHxD
580x1950x850 1160x1950x850 1160x1950x850 1740x1950x850
Mass(kg) 1000 1150 1500 1850
Controller Vibration Controller See Vibration Controller K2
Cooling Cooling Method Air cooling
Blower Dimensions
(mm)WxHxD*6
1280x2540x844 1280x2540x844 1462x2800x930 1462x2800x930
Mass(kg) 268 268 536 536
Wattage(kw) 18.5 18.5 30 30
Duct Hose
Diameter(φ)
250 250 250 250
  • *1 Random force ratings are specified in accordance with ISO5344 conditions. Please contact IMV or your local distributor with specific test requirements.
  • *2 Power supply: 3-phase 200/220/380/400/415 V, 50/60 Hz. A transformer is required for other supply voltages.
  • *3 In case of 200 V
  • *4 Above 4000 Hz, the force rolls-off at a rate of -6 dB/oct.
  • *5 Above 2000 Hz, the force rolls-off at a rate of -12 dB/oct.
  • *6 Spec described above is in case of 60Hz. Dimension is changed in case of 50Hz.
  • * The specification shows the maximum system performance. For long-duration tests, de-rating by up to 70% must be applied. Continuous use at maximum levels may cause failure.
  • * In the case of Random vibration test, please set the test definition of the peak value of acceleration waveform to be operated less than the maximum acceleration of Shock.
  • * Frequency range values vary according to sensor and vibration controller.
  • ** E/L is required for exporting the shaker system of over 50 kN Sine force.